Address: Wuqing Development Zone, Tianjin. Tel: +86-22-29342624, +86-15603054293. Email: [email protected] drilling fluid circulating system is like a close loop electric circuit through which drilling fluid (i.e. mud) can travel from the surface to all the way downhole and back to its initial point (i.e. mud pit).
Centrifugal pumps are widely used in various industries for the transfer of fluids. One common practice in operating centrifugal pumps is to start the pump with the discharge valve closed. This may seem counterintuitive to some, but there are valid reasons behind this practice.
>If you start the pump discharge valve closed, it means no discharge head minimum resistance to the pump and minimum current drawn. Even though current taken during startup is more than normal, by closing discharge valve you can avoid extra load on the pump. >If you have a
Centrifugal Pump Discharge Valve Closed
When a centrifugal pump is started with the discharge valve closed, it reduces the initial power demand on the pump motor. This is because when the discharge valve is closed, there is no flow of fluid through the pump, which means less resistance for the pump to overcome. As a result, the pump motor does not have to work as hard to start the pump.
Pump Discharge Valve Closed
Another reason for starting the pump with the discharge valve closed is to prevent damage to the pump. When a centrifugal pump is started with the discharge valve open, it can cause a surge of fluid through the pump. This sudden surge of fluid can create water hammer, which can damage the pump impeller, casing, and other components.
Discharge Valve Closed When Starting Pump
By keeping the discharge valve closed when starting the pump, it allows the pump to gradually build up pressure within the system. This gradual increase in pressure helps to prevent water hammer and ensures a smooth start-up of the pump. Once the pump is up and running smoothly, the discharge valve can be slowly opened to allow the fluid to flow through the system.
By starting the pump with the discharge valve closed the power demand made by the pump on the pump motor is kept to a very minimum. After the pump has started and the …
GN Solids Control System,China solids control equipment top manufacturer,Solids Control Specialist for Oil Gas Drilling Mud and HDD Fluids System. Tel:+86-18701560173 E-mail: sales@ . 14 Inch High Speed Centrifuge; 18 Inch Decanter Centrifuge; 22 Inch Decanter Centrifuge . HDD & CBM Mud Recycling System . TBM and Bored Pile Desanding Plant .